High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet

Product Details
Customization: Available
Type: Distribution Metering Box
Structure: Fixed Board
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
  • High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Operating conditions
  • Features
  • Applicable scene
  • Factory environment
  • Our Advantages
Overview

Basic Info.

Model NO.
GZDW
Form
Partly-welded Type
Operation Voltage
Low Voltage
Size
1 Uint
Application Range
High-rise Buildings
Shell Material
Stainless Steel
Shell Protection Grade
IP30
Brand
Vouchivan
Voltage
110V/220V
Color
Grey
Product Name
DC Power Supply Panel
Application
Industrial
Function
Electric Energy Distribute
Usage
Overcurrent Protection
Surface Treatment
Powder Coating Spray
Frequency
50/60Hz
Phase
3 Phase
AC Input Voltage
380V
Transport Package
Wooden Case / According Customers′ Demands
Specification
GZDW
Trademark
Vouchivan
Origin
Jiangsu, China
HS Code
8504333000
Production Capacity
50pieces/Day

Product Description

Product Description
DC panel used in large, middle and small power generating plant or substation, output DC source for the ON/OFF operation, relay protection, auto control, high voltage switches at normal status or fault status. The reliability of the DC panel is what other power source devices can't substitute always. It can meet with such high reliability for the auxiliary power source in substation and power plant.

High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel CabinetHigh Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel CabinetHigh Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet

Product Parameters

Parameter

Value

1. Input power voltage

three-phase AC 380V+10%, 50Hz5%

2 Output DC voltage rating

24v; 48v; 10;: 20;:

3. Output DC current value

5A, 8A, 10A.15A, 20A, 30A.40A, 50A, 80A, 100A, 150A, 200A, 250A.

4. Rated battery capacity

 

5. Voltage adjustment range (see table below)

10Ah, 20Ah, 38Ah, 40Ah, 50Ah, 60Ah, 65Ah, 80Ah, 100Ah, 150Ah, 200Ah, 250Ah, 300Ah, 400Ah.

6. Output DC current adjustment range

0~100% of the rated value

7. Stable accuracy

< ±1%

8. Steady flow accuracy

<±1%

9. Ripple coefficient

<1%

10. Overall noise

<55dB

11. Main transformer temperature rise

70C

12. Working method

continuous work

13. Efficiency

> 90%

14. Protection class

IP20-IP30

Operating conditions
  1. Ambient Temperature: No more than +50ºC and no less than -10ºC.

  2. Altitude: No more than 2000m.

  3. Relative Humidity: the average daily value is no more than 95% Jhe average monthly value is no more than 90%. 

  4. (Earthquake Intensity: No more than 8 degrees.

  5. Installation locations: without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.

  6. Installation Site: Indoor.

  7. Installation mode: anchor bolt. welded.

Features
  1. Display Operation Unit: This panel adopts new PMS intelligent touchable interface display which is not only intuitive, but also very easy for setting system running parameters. Up to 255 parameters pictures can display nearly all running parameters including voltage value of every battery unit (or every battery group). Advanced touchable interface display replaces traditional pushbuttons, which can increase system reliability further.

  2. AC power Distribution Unit: Using 2 ways of AC charging power supply lines, users can access 1 or 2 ways according to actual conditions. The system is distributed to each power module according to the principle of first route priority power supply.

  3. Power output unit: it selects high frequency switching power supply module and uses N+1 mode. After the failure of individual modules, it will automatically exit operation without affecting the normal operation of the system. The reliability of the whole system is improved. The module can be live plugged, which makes the maintenance work very simple. The high frequency switching power module uses power factor correction technology and phase correction technology to reduce the influence of the system on the computer harmonica. The double closed loop voltage and current regulation technology and the unique current bending current sharing technology make the distribution of the output current of each module reasonable and effective, and ensure the power system is always in the best operation status.

  4. Monitoring unit: it uses high performance microcomputer, scans and controls each unit in the system in real time, and provides high quality DC output to the control bus. At the same time, its V-T curve controls the equalizing charge voltage and floating charge voltage of the battery, according to the ambient temperature parameters of battery operation, ensuring the battery is full capacity and in good condition. In addition, the monitoring system monitors the voltage curve of each battery, so as to facilitate the timely deletion of the battery.

Applicable scene

High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet

Factory environment
High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet
High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet

 

Our Advantages

High Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel CabinetHigh Resistance to Lightning Strikes Gzdw Electric Switchgear DC Electric Panel Direct Current Panel Cabinet

 

Q1. Are you a factory or trading company?
A1.We are a factory.

Q2.Can I order a GZDW DC Power Switchgear sample?
A2:Yes, we accept any sample orders.

Q3: Could I have prices of your products?
A3: Welcome. Please feel free to send us an inquiry here. We will reply you within 24 hours.