Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
  • Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Arc-extinguishing Medium
SF6
Installation
Open Frame
Structure
ACB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
CCC
Model Number
Lw58 - 252
Rated Voltage
220kv
Rated Current
2500A
Frequency
50/60Hz
Pole No.
1
Transport Package
Wooden Case
Specification
20KG
Trademark
Vouchivan
Origin
Xuzhou, China

Product Description

Product Description
Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv
No.
Description
Technical parameters
1
Rated voltage, kV
72.5
126
145
252
3
Rated frequency, Hz
50/60
4
Rated current, A
1600~4000
3150~4000
 
1min Power frequency withstand voltage
140
230
265
460
 
Lightning impulse withstand voltage
325
550
650
1050
5
Rated short-circuit breaking

current, kA
25~40
40~63
7
Rated short circuit breaking

current (peak), kA
63~ 100
100~ 157.5
8
Rated short duration, s
3
3
3
3
 
Rated out-of-phase breaking current
10
10
10
10
 
Rated cable(line) charging

breaking current
10
31.5
50
125
 
Rated gas pressure, Mpa
0.4
0.5
0.5
0.6
 
Operation sequence
O-0.3s-CO- 180s-CO
 
SF6 gas leakage rate (per year)
≤1%
14
First of several genes
1.5
1.55
1.5
1.3
 
Main loop resistance, μΩ
≤40
≤45
≤45
≤50
 
Heater voltage
AC220
 
Control circuit and signal circuit voltage
DC220, DC230
 
Motor voltage
DC220, DC230


Description

Outdoor Sulfur Hexafluoride (SF6) dead tank  circuit breakers,

  • Rated voltage : 69 KV
  • Rated Continuous current : 1200 A / 1250A/1600A /2000A
  • Interrupting current rating:  31.5 KA
  • Frequency :  50 /60 Hz
  • Basic insulation level (BIL):  350 KV
  • With 6 pcs 150:5 ratio relaying accuracy bushing current transformers (CT)
  • Outdoor usage, with 3 pcs SF6 interrupters
  •  6-terminal pads with 4-hole each
  • Trip-free spring operation mechanism
  • 12-stages auxiliary contacts
  • Anti-condensation cabinet heater
  • Control wiring and terminal blocks
  • 110VDC trip coil
  • 48 VDC /110VDC closing coil
  • 110 /220 VDC Auxiliary voltage
  • with operation handle
  • with isolating switches
  • mechanical position indicator
  • CB frame grounding terminal holes
  • hot-dipped galvanized mounting structure
  • with gas charging device with regulator valve
  • with gas leak detector
  • with spare SF6 gas

 Circuit breakers meet the requirements specified in EN 62271-1, EN 62271-100, EN 60273, and other relevant EN (IEC) standards.

Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv

220KV 3Ph Live Tank SF6 Gas Circuit Breaker
LW Series self-energy SF6 Circuit Breaker is a three-pole/single-pole AC 50Hz/60Hz outdoor high voltage power transmission equipment for the division of the rated current, fault current or conversion lines, transmission and distribution system for protection, control and operation can be opening, closing and fast automatic reclosing operation. The circuit breaker using the latest design principles, has a simple structure, small size, low supplies, the energy needed to operate a small, high reliability, easy installation, low noise characteristics. Is my company developed a new generation of high voltage SF6 circuit breakers.

Service environment

1. Ambient temperature: -40 ºC ~ +50 ºC.
2. Daily average ambient air relative humidity ≤ 95%, on average ≤ 90%;
3. Wind pressure: less than 700pa.
4.Altitude: less than 3000m.
5.Earthquake intensity: not more than 9 degrees.
6. Air Contamination: 3 grade.
Outdoor Installation 3 Phase Automatic Motorized Sf6 Gas Insulation Load Break Switch Lbs 30kv 33kv 35kv 36kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier