VS1-12 side-mounted type vacuum circuit breaker is a kind of indoor high voltage switch device which is used in the AC Three-phase power system of frequency 50HZ,rated voltage 12KV to be the protection and control unit. Because of the special superiority of vacuum circuit breaker, especially suitable for applications that require frequent operation at rated operating Current or multiple open short-circuit breaking current location. It 1s especially suitable to the place requiring frequent operations.
VS1-12 side-mounted type vacuum circuit breaker adopts fixed installation, which is mainly used in the fixed switchgear. It can be used alone or used in ring network power supply system, box-type variable system and non-standard power supply system to protect and control the Transmission and distribution line.
No. |
Item |
Units |
parameters |
|||
1 |
Rated voltage |
KV |
12 |
|||
2 |
Rated insulation level |
Rated Lightning Impulse voltage tolerance |
KV |
75 |
||
1min Frequency voltage |
42 |
|||||
3 |
Rated short-circuit breaking current |
KA |
20/25 |
31.5 |
40 |
|
4 |
Rated current |
A |
630 1250 |
630 1250 1600 2000 2500 3150 |
1250 1600 2000 2500 3150 4000 |
|
5 |
Rated thermal stability of current (RMS) |
KA |
20/25 |
31.5 |
40 |
|
6 |
Dynamic Stability rated current (peak |
63 |
80 |
100 |
||
7 |
Rated short-circuit closing current (peak) |
63 |
80 |
100 |
||
8 |
Rated short-circuit breaking current breaking number |
times |
50 |
|||
9 |
Frequency tolerance of the secondary circuit voltage (1min) |
V |
2000 |
|||
10 |
Rated operating sequence |
0-0.3s-CO-180s-CO |
||||
0-180s-CO-180s-CO(40kA) |
||||||
11 |
Rated thermal stabilization time |
S |
4 |
|||
12 |
Rated a single / back-to-back electric current breaking device group |
630/400 800/400(40KA) |
||||
13 |
Mechanical Endurance |
Cycles |
10000 |
1. Ambient air temperature: upper limit +40 degrees, lower limit -40 degrees;
2. Altitude: ≤2000m (if the altitude increases, the rated insulation level will be increased accordingly);
3. Wind pressure: no more than 700Pa (equivalent to wind speed of 34m/s);
4. Earthquake intensity: no more than 8 degrees;
5. Contamination level: level;
6. Maximum daily temperature difference: no more than 25 degrees;
7. Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;
8. Places without inflammability, explosion hazard, chemical corrosion and severe vibration.
High reliability Suitable for reclosing operations of all characteristics.
all operating conditions the use of vertical insulating cylinders to defend against all special environmental influences.
maintenance-free solid insulated construction - integrated sealed poles.
Versatile and multi-purpose Can be fixed or removable and can be mounted on a frame
Standardised design Good interchangeability and versatility, particularly suitable for use with KYN28 (GZS1)
Q1. Are you a factory or trading company?
Q2:How do you control the quality ?
A2:Professional QC team comply with TQM insure you the quality. Each step is in compliance to the standards,At the same time ,we will take photos or shoot video for you.