30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
  • 30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
S22-M-30/10
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Low Frequency
Shape of Core
EE
Brand
Vouchinvan
Power Rating
up to 2500kVA
Frequency
up to 100kHz
Windings
Copper and Aluminum
Voltage Class
up to 35kv
Bil Ratings
up To125 Kv
Cooling
Self,Forced and Water
Transport Package
Wooden Case
Specification
30KVA
Trademark
Vouchivan
Origin
Xuzhou, China
HS Code
8504210000
Production Capacity
7000mva/Year

Product Description

30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
Product Description

 

We ensure each one of our delivered transformers had passed the full acceptance test and we remains 0 fault rate record for more than 10 years so far, oil immersed power transformer is designed in accordance with IEC, ANSI and other major international standards.
 

Scope of Supply

Product: Oil Immersed Power Transformer

Rated Power: Up to 200 MVA

Primary Voltage: Up to 230 KV

Rated capacity (KVA) Voltage Combination andTap range Vector group Symbol No-load loss                        (W) Load loss (W)  75 Impedance Voltage(%) No-load current
HV(KV) HVTap range(%) LV(KV)
30 6     6.3     10    10.5   11 ±5%     or ±2*2.5% 0.4 Dyn11 65 455 4 1.5
50 80 655 1.3
63 90 785 1.2
80 105 945 1.2
100 120 1140 1.1
125 135 1360 1.1
160 160 1665 1
200 190 1970 1
250 230 2300 0.9
315 270 2760 0.9
400 330 3250 0.8
500 385 3900 0.8
630 460 4460 4.5 0.6
800 560 5400 0.6
1000 665 7415 0.6
1250 780 8640 0.5
1600 940 10440 0.5
2000 1085 13180 5 0.4
2500 1280 13660 0.4


Power Transformer Manufacturing

30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
Our Team Will Make The Best Product Solution For Your Project.

Oil immersed power transformer has obtained multiple certifications and its product quality is favored by customers.
If you need the special certificate we can do it.
30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test
Transformers Cores Matericals,we can customized two kinds of : Amorphous Alloy Cores or Silicon Steel Cores.

Power Transformers Coil Matericals,we also can customized two kinds of : Copper Coil or Aluminum Coil.
and There are more technologies to meet your needs.
I hope recive your massage.

Why this information about custom Power transformer,Distribution transformer,Subtation transformer,Special transformer?
Because our factoy have more than 300 engineering and technical personnel,more than 1200 employees,covering an area of 360000 square meters.
In the last, our prices are reasonable and cheap, guaranteed to fit your purchasing plan.Don't worry you plan.
We welcome all future partners to visit our factory and office.


Packing and Delivery Transformer
30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test

Why Do Transformers Fail?

An electrical transformer can blow for a variety of reasons and can cause an explosion or fire. Causes of transformer explosions could include:

· Lightning strikes

· Overheating

· Wear and corrosion

· Damage to the electrical system anywhere along the line

· Failed safety devices and power surges

· Foreign objects or animals getting into the transformer

· Moisture

When a transformer fails, it will usually result in a loud boom, a power outage, and a fireball that creates a large plume of smoke.

30kVA 10.5kv Three Phase Oil Immersed Transformer for Electrical Equipment Special Test

The final assembly begins with the removal of the core and coil assembly from the vapor phase. All internal components are re pressed under the pressure specified by the project, and now the excess water has been removed to ensure the tightness. The metal and fiber nuts are tightened or tightened as required, and the electrical clearance is verified again.

 

The core and coil assembly are placed in the tank, which is filled with oil to prevent exposure to air, and a cover assembly is added to connect with the sleeve. Once the enclosure is welded and leak checked, the galvanized radiator is assembled to the tank, the unit is drained, and the transformer is vacuum filled for final testing. During this period, the control box and any other customer specified monitors and components are installed and connected. All external welded components shall be installed to ensure correct installation to the tank and removed prior to the completion of the factory acceptance test of the transformer.

FAQ
1. What standard do you follow?
EU548/2014,IEC 60076 standard, and all other major international standard such as ANSI, CSA, UL, etc.
2. What package do you have for transformers?
Standard package with welded iron frame packed with ply wood boxes.
3. How long can I receive my transformers?
The shipping time from our port (lianyungang or qingdao) to your port is range from one week to one month, depend on the distance.
4. What is your delivery time?
Normally within one month since the date drawing approved by customer except the transformer required tap changer.
5. How can you support us as a partner?
We will offer you the best price, best service and other supporting documents such as quotation, technical data sheet, drawing, reference list, manufacturing plan, quality control plan, testing plan, test report, etc.
6. What is ur service?
We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, aiming to be your best trustworthy partner.
7. Where is your main market?
We had exported our transformers to more than 30 countries in the world, our main market is Africa countries, South and North American countries, and Asia countries.
8. What certificate do you have?
We have KEMA, CESI, CTQC type test report for our transformers.
9. How long is your delivery time?
30 days after drawing confirmed by buyer for distribution transformers below 5000kva, bigger transformers depend on the capacity and components, normally 30-90days(with imported components)
10. What is the scope of your after-sale service?
Installation, commissioning, training, maintenance, etc.
11. Why choose VOUCHIVAN?
Experienced transformer supplier with professional engineering team.
Complete customer service from quoting to operating.
Quick response 24/7.
12. Are you able to do the installation and commissioning?
Sure, we will charge extra cost for this service.