Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
  • Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
Overview

Basic Info.

Model NO.
SH15-M-315/10
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Low Frequency
Shape of Core
EE
Brand
Vouchinvan
Power Rating
up to 2500kVA
Frequency
up to 100kHz
Windings
Copper and Aluminum
Voltage Class
up to 35kv
Bil Ratings
up To125 Kv
Cooling
Self, Forced and Water
Transport Package
Wooden Case
Specification
50KVA
Trademark
Vouchivan
Origin
Xuzhou, China
HS Code
8504210000
Production Capacity
7000mva/Year

Product Description

The Features of Our Transformer:

-Low loss
-Low noise
- High efficiency
-Easy maintenance
- Operation reliability
-Pretty outline and compact structure
-Strong mechanical strength and short-circuit withstand ability
-100% guaranteed no leakage
Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
Transformer, Power Transformer, Electrical Transformer manufacturer / supplier in China, offering Hot Sales 11kv Oil Immersed Transformer Manufacturers 11kv 200kVA Power Distribution Transformer Oil Transformer with CB CE ISO9001, 150 160 200 250 1250 kVA Industrial Mv Hv Electric High Voltage Distribution Manufacturers Volt Oil Power Transformer, 1 5 Mva 10 100 1000 kVA 3 Phase Step up Down High Voltage Hermetically Sealed Hv Power Supply Oil Immersed Transformer Price and so on.


Oil Immersed Power 500 kVA 33 Kv Step Down Distribution TransformerWe ensure each one of our delivered transformers had passed the full acceptance test and we remains 0 fault rate record for more than 10 years so far, oil immersed power transformer is designed in accordance with IEC, ANSI and other major international standards.
 The 2000 kVA Oil type distribution transformer was delivered to Ethiopia in 2021.
 
The rated power of the transformer is 2000 kVA with ONAN cooling, the primary voltage is 33kV with ±2*2.5% tapping range (NLTC), the secondary voltage is 0.4kV, they formed a vector group of Dyn5.
 
Our 2000 KVA distribution transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.
We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!
 
Scope of Supply
Product: Oil Immersed distribution Transformer
Rated Power: Up to 5000 KVA
Primary Voltage: Up to 35 KV
 
Technical Specification
2000 KVA transformer specifications type and data sheet
Delivered to Ethiopia
Year 2021
Model S-M-2000 kVA-33/0.4kV
Type Distribution Transformer
Standard IEC60076
Rated Power 2000 kVA
Frequency 50 HZ
Phase Three
Cooling Type ONAN
Primary Voltage 33 kV
Secondary Voltage 0.4 kV
Winding Material Copper
Vector Group Dyn5
Impedance 5.5 -> 6 %
Tap Changer NLTC
Tapping Range ±2*2.5%
No Load Loss 1667 W
On Load Loss 19800 W
Accessories Standard Configuration
Remarks N/A
 
2000 kVA-33/0.4kV Transformer Drawing
2000 kVA transformer diagram drawing and size.
Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer

Scope of Supply

Product: Oil Immersed Power Transformer

Rated Power: Up to 200 MVA

Primary Voltage: Up to 230 KV
 

Rated capacity (KVA) Voltage Combination andTap range Vector group Symbol No-load loss                        (W) Load loss (W) Impedance Voltage(%) No-load current
HV(KV) HVTap range(%) LV(KV) Yy Dd
30 6     6.3     10    10.5   11 ±5%     or ±2*2.5% 0.4 Yyn0    or  Dyn11 33 600 630 4 1.5
50 43 870 910 1.2
63 50 1040 1090 1.1
80 60 1250 1310 1
100 75 1500 1580 0.9
125 85 1800 1890 0.8
160 100 2200 2310 0.6
200 120 2600 2730 0.6
250 140 3050 3200 0.6
315 170 3650 3830 0.5
400 200 4300 4520 0.5
500 240 5150 5410 0.5
630 320 6200 6200 4.5 0.3
800 380 7500 7500 0.3
1000 450 10300 10300 0.3
1250 530 12000 12000 0.2
1600 630 14500 14500 0.2
2000 750 18300 18300 5 0.2
2500 900 21200 21200 0.2
Product Description

Power Transformer Manufacturing

Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
Our Team Will Make The Best Product Solution For Your Project.

Oil immersed power transformer has obtained multiple certifications and its product quality is favored by customers.
If you need the special certificate we can do it.

Oil Immersed Power 500 kVA 33 Kv Step Down Distribution TransformerTransformers Cores Matericals,we can customized two kinds of : Amorphous Alloy Cores or Silicon Steel Cores.

Power Transformers Coil Matericals,we also can customized two kinds of : Copper Coil or Aluminum Coil.
and There are more technologies to meet your needs.
I hope recive your massage.

 

Oil Tank:

1. The oil tank is a transformer housing containing the iron core, winding and transformer oil.

2. The corrugated tank structure is fully sealed, and the corrugated will expand and compress with the increase of oil, isolating the transformer from the atmosphere and preventing oil deterioration and moisture. After oil removal, rust removal and phosphating treatment, the surface of corrugated oil tank is coated with rainproof paint. Moisture and salt spray.


Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer
Why this information about custom Power transformer,Distribution transformer,Subtation transformer,Special transformer?
Because our factoy have more than 300 engineering and technical personnel,more than 1200 employees,covering an area of 360000 square meters.
In the last, our prices are reasonable and cheap, guaranteed to fit your purchasing plan.Don't worry you plan.
We welcome all future partners to visit our factory and office.

 
Our Advantages

 

How to Reduce Transformer Losses
Transformers are widely used in electric power systems to transfer electrical energy from one circuit to another. However, due to various factors such as resistance, eddy currents, and hysteresis, they can experience energy losses, which decrease their efficiency and increase operating costs. In order to optimize transformer performance, it is critical to understand how these losses can be minimized. In this blog, we will discuss some strategies for reducing transformer losses.
1. Choose the right core material
Using the right core material can greatly reduce transformer losses. Transformer cores are made from magnetic materials such as iron or steel, which can be laminated to reduce eddy currents. High-quality cores that are designed for low loss can improve transformer efficiency.
2. Optimize the winding design
The winding design is another factor that can affect transformer losses. A proper winding design with the right number of turns, correct wire gauge, and uniform winding distribution can minimize losses due to resistance. This can be achieved through careful analysis and simulation of the transformer design.
3. Use high-quality insulation
The insulating material used in the transformer plays a critical role in reducing losses due to hysteresis and eddy currents. High-quality insulating materials such as mica and varnish can provide better insulation and reduce energy losses.
4. Maintain proper cooling
Transformers generate a lot of heat during operation, and overheating can increase energy losses and reduce transformer life. Proper cooling systems such as fans, radiators, or oil-cooling can remove excess heat and ensure efficient operation.
5. Reduce load losses
Load losses occur when the transformer is under load, and can be reduced by improving the power factor, reducing voltage drop, or choosing the right transformer size. Monitoring load losses and optimizing load factors can significantly reduce energy consumption.
In conclusion, transformer losses can be reduced through careful selection of core materials, optimization of winding design, use of high-quality insulation, proper cooling, and load management. By implementing these strategies, transformer efficiency can be improved, resulting in reduced energy consumption, lower operating costs, and increased reliability.
Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer

Product Advantages

- Authoritative product certification: ISO, CE, CCC, etc

- Perfect SQA quality management system to ensure high quality products

- Quick quotation, can provide electrical design services

- The delivery period is short, and the fastest delivery time is 10-15 days worldwide

- Perfect after-sales service system, so that customers buy worry-free

- Welcome customers to visit the factory guidance, provide OEM/ODM

If you are interested in becoming our company's foreign agent,please contact us!
Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer

Why Do Transformers Fail?

An electrical transformer can blow for a variety of reasons and can cause an explosion or fire. Causes of transformer explosions could include:

· Lightning strikes

· Overheating

· Wear and corrosion

· Damage to the electrical system anywhere along the line

· Failed safety devices and power surges

· Foreign objects or animals getting into the transformer

· Moisture

When a transformer fails, it will usually result in a loud boom, a power outage, and a fireball that creates a large plume of smoke.

Oil Immersed Power 500 kVA 33 Kv Step Down Distribution Transformer

The final assembly begins with the removal of the core and coil assembly from the vapor phase. All internal components are re pressed under the pressure specified by the project, and now the excess water has been removed to ensure the tightness. The metal and fiber nuts are tightened or tightened as required, and the electrical clearance is verified again.

 

The core and coil assembly are placed in the tank, which is filled with oil to prevent exposure to air, and a cover assembly is added to connect with the sleeve. Once the enclosure is welded and leak checked, the galvanized radiator is assembled to the tank, the unit is drained, and the transformer is vacuum filled for final testing. During this period, the control box and any other customer specified monitors and components are installed and connected. All external welded components shall be installed to ensure correct installation to the tank and removed prior to the completion of the factory acceptance test of the transformer.

 

Routine tests of transformer include:

1.Winding resistance test of transformer

2.Transformer ratio test

3.Transformer vector group test

4.Measurement of impedance voltage/short circuit impedance (principal tap) and load loss (Short circuit test)

5.Measurement of no-load loss and current (Open circuit test)

6.Measurement of insulation resistance

7.Dielectric tests of transformer.

8.Tests on on-load tap-changer.

9.Oil pressure test on transformer to check against leakages past joints and gaskets
 

FAQ
1. What standard do you follow?
EU548/2014,IEC 60076 standard, and all other major international standard such as ANSI, CSA, UL, etc.
2. What package do you have for transformers?
Standard package with welded iron frame packed with ply wood boxes.
3. How long can I receive my transformers?
The shipping time from our port (lianyungang or qingdao) to your port is range from one week to one month, depend on the distance.
4. What is your delivery time?
Normally within one month since the date drawing approved by customer except the transformer required tap changer.
5. How can you support us as a partner?
We will offer you the best price, best service and other supporting documents such as quotation, technical data sheet, drawing, reference list, manufacturing plan, quality control plan, testing plan, test report, etc.
6. What is ur service?
We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, aiming to be your best trustworthy partner.
7. Where is your main market?
We had exported our transformers to more than 30 countries in the world, our main market is Africa countries, South and North American countries, and Asia countries.
8. What certificate do you have?
We have KEMA, CESI, CTQC type test report for our transformers.
9. How long is your delivery time?
30 days after drawing confirmed by buyer for distribution transformers below 5000kva, bigger transformers depend on the capacity and components, normally 30-90days(with imported components)
10. What is the scope of your after-sale service?
Installation, commissioning, training, maintenance, etc.
11. Why choose VOUCHIVAN?
Experienced transformer supplier with professional engineering team.
Complete customer service from quoting to operating.
Quick response 24/7.
12. Are you able to do the installation and commissioning?
Sure, we will charge extra cost for this service.
 