LV withdrawable switchgear is suitable for distribution system of power plant, high building and some lines, such as petroleum chemistry and industry, metallurgy, textile, etc. It is applicable for distribution, motor centralized control, reactive power compensation in power generation and power supply system of three phase AC 50/60Hz, rated voltage 380V(400V,600V), rated current 4000A and below, where require high automation and interfaces with computers.
Number |
Parameter |
value |
|
1 |
Main circuit rated voltage (V) |
AC 400/660 |
|
2 |
Auxiliary circuit rated voltage |
AC 220,380(400),DC 110,220 |
|
3 |
Rated frequency (HZ) |
50(60) |
|
4 |
Rated insulation voltage (V) |
660 |
|
5 |
Rated current (A) |
horizontal bus |
≤5000 |
6 |
Rated current (A) |
Vertical Busbar (MCC) |
1000 |
7 |
Busbar rated short-time withstand current (KA/1s) |
50,80 |
|
Busbar rated peak withstand current (KA/0.1s) |
105,176 |
||
8 |
Power frequency test voltage (V/1min) |
The main circuit |
2500 |
Auxiliary circuit |
2000 |
||
9 |
busbar |
Three-phase four-wire system |
A.B.C.PEN |
Three-phase five-wire system |
A.B.C.PEN |
||
10 |
Protection class |
IP30, IP40 |
Model meaning
Operating conditions
1. The ambient air temperature should not be higher than +40°C, not lower than -5°C, and the average temperature within 24 hours should not be higher than +35°C. When it exceeds, the derating operation shall be performed according to the actual situation;
2. For indoor use, the altitude of the site of use shall not exceed 2000m;
3. The relative humidity of the surrounding air does not exceed 50% when the maximum temperature is +40°C, and a larger relative humidity is allowed at lower temperatures, such as 90% at +20°C, which should be considered due to temperature changes. Accidental effects of condensation;
4. When the device is installed, the inclination from the vertical plane should not exceed 5, and the entire group of cabinets should be relatively flat (in line with GBJ232-82 standard);
5. The device should be installed in a place without severe vibration and shock and not enough to cause the electrical components to be corroded;
6. When users have special requirements, they can negotiate with the manufacturer.
LV withdrawable switchgear is suitable for distribution system of power plant, high building and some lines, such as petroleum chemistry and industry, metallurgy, textile, etc. It is applicable for distribution, motor centralized control, reactive power compensation in power generation and power supply system of three phase AC 50/60Hz, rated voltage 380V(400V,600V), rated current 4000A and below, where require high automation and interfaces with computers.