Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Steel Plate
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
  • Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Installation Instructions
  • Factory environment
  • Applicable scene
  • Our Advantages
Overview

Basic Info.

Model NO.
KYN61-40.5KV/2000A
Voltage Level
40.5kv
Installation
Fixed
Structure
Withdrawable
Current
AC
Model No.
Kyn61 Series Enclosed Switchgear
Frequecy
50Hz
Protection Level
IP4X
Ambient Temperature
-25-40 Degrees
Provide Machining Customization
Yes
Structural Form Cabinet
Type
Structural Form
Floor-Standing
Use
Power Distribution
1min Power Frequency Withstand Voltage
95 Kv
Installation Method
Fixed
Lightning Impulse Withstand Voltage
185kv
Scope of Application
Outdoor
Place of Sale
Worldwide
Transport Package
Wooden Case / According Customers′ Demands
Specification
KYN61-40.5
Trademark
Vouchivan
Origin
Jiangsu Xuzhou
HS Code
8504333000
Production Capacity
50pieces/Day

Product Description

 

Product Description

KYN61-40.5 armored shift type AC metal closed switchgear is used in 40.5kV three-phase AC 50Hz power system, as power plants, substations and industrial and mining enterprises to accept and distribute electric energy; It has the functions of controlling, protecting and detecting the circuit. In addition to being widely used in general power systems, it can also be used in places with frequent operations.

Detailed Photos


Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear

Product Parameters

Main technical parameters of switchgear
Project Unit Data
Rated voltage KV 40.5
Rated insulation
level
1min.P.F. withstand voltage(phases to ground/gaps) KV 95(lsolation fracture 115)
Lightning impulse withstand voltage(phases to ground/gaps) KV 185(lsolation fracture 115)
Rated frequency Hz 50
Main busbar rated current A 630- 2500  3150
Rated short-circuit breaking current A 31.5
Rated short-time withstand current(4s) KA 25
Rated peak withstand current KA 31.5
Auxiliary control loop rating V 25

ZN85-40.5Vacuum circuit breaker technical parameters
Project Unit Data
Rated voltage KV 40.5
Rated insulation
level
1min.P.F. withstand voltage(phases to ground/gaps) KV 95(lsolation fracture 115)
Lightning impulse withstand voltage(phases to ground/gaps) KV 185(lsolation fracture 115)
Rated frequency Hz 50
Rated current A 600,1000,1250,1600   1250,1600,2000,
2500,3150
Rated short-circuit breaking current A 25 31.5
Rated peak withstand current KA 63           80
Rated operation sequence   O-0.3s-CO-180sCO
Rated short-circuit breaking current breaking times time 20
 Rated cable charging breaking current A 25
Rated capacitor bank breaking current A 400
Capacitive current opening and closing performance garde C2
Closing time ms 40-100
Opening time ms 30-60

VD4Vacuum circuit breaker technical parameters
Project Unit Data
Rated voltage KV 40.5
Rated insulation
level
1min.P.F. withstand voltage(phases to ground/gaps) KV 95(lsolation fracture 115)
Lightning impulse withstand voltage(phases to ground/gaps) KV 185(lsolation fracture 115)
Rated frequency Hz 50
Rated current A 1250,1600,2000,2500,3150
Rated short-circuit breaking current A 31.5
 

Installation Instructions

Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit SwitchgearConditions of Use

The altitude does nat exceed 1000m;
Ambient temperature:-25ºC-+40ºC;
The daily average is not more than 95%, and the monthly average is not more than 90%;
There are no flammable gases, explosion hazards, serious contamination, chemical corrosion and freguent severe vibrations.


Special use environmental conditions
1,When the switchgear is used under normal environmental conditions as specified in this instruction manual, the company andthe user may negotiate and agree on special operating conditions that exceed normal operating conditions.
2,In order to prevent condensation, the swltch cabinet is equlpped with a heater. When the switchgear is in standby, it should beput into use.Even in normal operation, you should pay attention to the application.
3,The heat dissipation problem of the switchgear can be salved by additional ventilation.


Main feature
The cabinet is made of aluminum-zinc plate and processed by CNC equipment. lt is formed by bolting or riveting. The
structure is fully assembled.
lt can be equipped with 2N85-40.5 vacuum circuit breaker handcart, VN1, VD4 or HD4 vacuum circuit breaker handcart. Themain busbar of the switchgear can be connected without transition cabinet.
The space of the cable room is suficient, and the air clearance can be ensured to be more than 300mm. There is no need toinstall insulation spacers between the phases.

 

Factory environment

Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear

Applicable scene

Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear

Our Advantages

Kyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit SwitchgearKyn61-40.5kv/2000A Low Voltage Network Prefabricated Cabinet Electrical Substation Unit Switchgear

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier