Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (15)
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
  • Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
SGB10 -5 MVA-24.94/4.16 KV
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EE
Brand
Vouchinvan
Type
Resin Cast Dry Type Transformer
Standard
IEC60076
Cooling Type
an/Af
Winding Material
Aluminum
Vector Group
Dyn11
Impedance
4%
Tap Changer
Nltc
Tapping Range
±2*2.5%
Accessories
Temperature Controller, Cooling Fans
Transport Package
Wooden Case
Specification
5000kva
Trademark
Vouchivan
Origin
Xuzhou, China
HS Code
85042100

Product Description

 
Product Description


 

This 5 MVA Vacuum Impregnated Transformer was delivered to Canada in 2016. the rated power of the transformer is 5000 KVA. the primary voltage of the transformer is 24.94 KV and secondary voltage is 4.16 KV. This is VPI transformers, is a new concept of dry type transformers, the transformer coils are vacuum pressure impregnated in high temperature polyester vanish under vacuum and pressure, the coils can be made of copper or aluminum, the insulation is made of high grade nonflammable materials, the insulations class can be F, H or C class, suitable for different requirements. Our 5 MVA Dry Type Transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.

 

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings



What is VPI process?

Vacuum Pressure Impregnation (V.P.I) is a process by which a fully wound electric apparatus stator or rotor is completely submerged in a Resin. Through a combination of dry and wet vacuum and pressure cycles, the resin is assimilated throughout the insulation system.

 

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings

What is the difference between dry type transformer and oil?

Dry-type transformers use air as the cooling medium, while oil-filled transformers use oil instead of air. Some public places do not use oil-filled transformers because they are a big fire hazard and, instead, use dry-type transformers. This is because the liquid being used is flammable.


Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
Temperature control system

Built-in PT100 probes in 3 phase windings to detect the real-time temperature of windings and cycle display them in the digital screen.

Open circuit alarm and fault self-check alarm display and signal output.

3 stages automatically actions while the temperature reached to the set value, 1st stage the cooling fans start automatically, 2nd stage high temperature alarm,3rd stage over temperature trip.

Fans manual/auto control switch, timing start/stop, history data output.

4-20mA current output

RS485 Modbus communication protocol

Environment temperature measurement

Core temperature measurement

 

Dry Type Transformer Advantages:

1. No Fire Hazard

2. Safety for people and property

3. Outage customer costs

4. Ecological and Environmentally Friendly

5. Maintenance & Pollution Free

6. Suited for damp and/or contaminated

7. Excellent resistance to short circuit effect

8. Excellent capacity to support overload

9. Excellent performance toward seismic phenome

10. Saving Costs give lower installation related costs

11. Easy Installation


 
Scope of Supply
 

Product: resin cast dry type transformer

Voltage level: up to 35KV

Rating level: up to 20MVA

The transformer can be designed according to customer's requirements


 
Technical Specification
SGB 10
Rated capacity (KVA) Voltage Combination andTap range Vector group Symbol No-load loss                        (W) Load loss (W) Impedance Voltage(%) No-load current(%)
HV(KV) HVTap range(%) LV(KV)
30 6     6.3     10    10.5   11 ±5%     or ±2*2.5% 0.4 Dyn11 190 760 4.0  2.0 
50 270 1070 2.0 
80 370 1480 1.5 
100 400 1690 1.5 
125 470 1980 1.3 
160 540 2280 1.3 
200 620 2710 1.1 
250 720 2960 1.1 
315 880 3730 1.0 
400 980 4280 1.0 
500 1160 5230 1.0 
630 1300 6400 6.0  0.85 
800 1520 7460 0.85 
1000 1770 8760 0.85 
1250 2090 10300 0.85 
1600 2450 12500 0.85 
2000 3050 15500 0.70 
2500 3600 18400 0.70 
   
SGB 11
Rated capacity (KVA) Voltage Combination andTap range Vector group Symbol No-load loss                        (W) Load loss (W) Impedance Voltage(%) No-load current(%)
HV(KV) HVTap range(%) LV(KV)
30 6     6.3     10    10.5   11 ±5%     or ±2*2.5% 0.4 Dyn11 170 760 4.0  2.0 
50 240 1070 2.0 
80 330 1480 1.5 
100 360 1690 1.5 
125 420 1980 1.3 
160 480 2280 1.3 
200 550 2710 1.1 
250 640 2960 1.1 
315 790 3730 1.0 
400 880 4280 1.0 
500 1040 5230 1.0 
630 1170 6400 6.0  0.85 
800 1360 7460 0.85 
1000 1590 8760 0.85 
1250 1880 10300 0.85 
1600 2200 12500 0.85 
2000 2740 15500 0.70 
2500 3240 18400 0.70 


We ensure that each one of our delivered units has undergone rigorous full acceptance testing. We provide one-package service from consulting, quoting, manufacturing, installation, commissioning, training to after sale services, our products are now operating in more than 50 counties in the world. We aim to be your most reliable supplier as well as your best partner in business!

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings


Routine test

-Measurement of winding resistance
-Measurement of voltage ratio and check of phase displacement
-Measurement of short-circuit impedance and loss
-Measurement of no-load loss and current
-Dielectric routine tests
-Tests on on-load tap-changers, where appropriate
-Leak testing with pressure for liquid-immersed transformers(tightness test)
-Tightness tests and pressure tests for tanks for gas-filled transformers
-Check of the ratio and polarity of built-in current transformers
-Check of core and frame insulation for liquid immersed transformers with core or frame insulation


Type test

-Temperature-rise type test
-Dielectric type tests
-Determination of sound level for each method of cooling for which a guaranteed sound level is specified
-Measurement of the power taken by the fan and liquid pump motors
-Measurement of no-load loss and current at 90% and 110% of rated voltage


Special test

-Dielectric special tests
-Winding hot-spot temperature-rise measurement
-Determination of capacitances windings-to-earth, and between windings
-Measurement of dissipation factor(tanδ) of the insulation system capacitances
-Determination of transient voltage transfer characteristics
-Measurement of zero-sequence impedance(s) on three-phase transformers
-Short-circuit withstand test
-Measurement of d.c. insulation resistance each winding to earth and between windings
-Vacuum deflection test on liquid immersed transformers
-Pressure deflection test on liquid immersed transformers
-Vacuum tightness test on site on liquid immersed transformers

 

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy SavingsOUR PAKAGE:

Long time shipment & Seaworthy wooden box

Wooden package optional:
1,choose one unit/ wooden box
2,choose 2unit/ wooden box to save cost

Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
OUR SERVICE:

1,Quick response in before sales period help you got order
2,Excellent service in production time let you know each step we made
3,Reliable quality solve you aftersale headache
4,Long period quality waranty ensure you can buy without hesitate
Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
Vouchivan (VCV) transformer is the top transformer supplier in China.  The factory is located in Jiangsu Province,covering an area of 30,000 square meters.  With more than 20 years of transformer export experience,the professional technical team can meet your requirements for all technical standards;  the professional marketing team will quickly and efficiently promote your transformer project,saving you more time and economic costs.  Various international certifications of transformers to ensure product quality,safety and reliability.  The practical application of VCV Transformer in nearly a hundred countries will make you more confident in VCV Transformer.  VCV Transformer will be your good choice.
Factory Direct Sales 5 Mva Vacuum Pressure Impregnated Vpi Dry Type Transformer for Energy Savings
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now